Construction joint waterstops, internal, with extruded reinforcement and fixing loops, black, DIN 18541

 |
 |
Construction joint waterstops with fixing loops are reinforced one -sided with harder adjusted PVC P cords and have fixing loops on both edges of the waterstop. The protruding loops are for fastening the waterstop to the reinforcement (clamps are not required).
|
Construction joint waterstops, internal, with inlying round bar steel - stabilisation, black, DIN 18541

|
Our waterstops are available in two material qualities "DIN 18541 PVC-P-NBR combined polymerisat" and "Standard Specification PVC-P". Both materials are available in "NB" = not compatible with bitumen and "BV" = compatible with bitumen according to DIN 16937.
|
|
DIN 18541 PVC-P-NBR combined polymerisat (external quality control by MPA NRW)
|
attitude against bitumen: NB = not compatible with bitumen BV = compatible with bitumen
|
|
physical properties (extract)
|
waterstops, waterstops for capping joints and profiles
|
test according to DIN
|
|
Elongation at break at + 23° C
|
350 %
|
53455
|
|
|
Tensile strength
|
10 N/mm²
|
53455
|
|
|
Shore A-hardness
|
70 +- 2
|
53505
|
|
Waterstops and profiles without geometrically accordance to DIN 18541, will be delivered according to DIN 18541 part 2, table 1. Further applications must be specified separately.
|
|
|
Concerning the actual state of the DIBt (german institute of civil engeneering) in consultation with the authorities of construction inspection of the federal states created building regulations, for protection against pressing and not pressing water also against soil humidity, its only allowed to use waterstops in accordance to:
|
|
DIN 18541 or DIN 7865 or waterproofing systems
|
thermoplastic waterstops, weldable
elastomeric waterstops, vulcanisable
with AbP (general construction supervision certificate)
|
DIN V 18197 regulate the planning, dimensioning, conditioning, handling and the installation of waterstops.
|
|
Standard Specification PVC-P (internal quality control, without AbP)
|
attitude against bitumen: NB = not compatible with bitumen BV = compatible with bitumen according to DIN 16937
|
|
physical properties (extract)
|
waterstops, waterstops for capping joints and profiles
|
test according to DIN
|
|
Elongation at break at + 23° C
|
275 %
|
53455
|
|
|
Tensile strength
|
7,5 N/mm²
|
53455
|
|
|
Shore A-hardness
|
73 +- 2
|
53505
|
|
Waterstop intersection pieces Standard intersection pieces leg length 0,50 m (dimension between axes)

Waterstop intersection pieces and systems
On placing an order of standard intersection pieces, quantity, design, type of waterstop and material quality have to be declared. For making of waterstop systems it s necessary for us to have dimensioned as possible isometric system drawings with designation about type of waterstop and material quality. Every declared dimension has to be dimension between axes.

|
Examples of submission SFA
|
|
pos.
|
quantity
|
specification of services
|
unit price
|
all round price
|
|
|
...running meter
|
Leschuplast GLT construction joint waterstop, internal, reinforced DIN 18541, with extruded reinforcement and fixing loops or with inlying round bar steel - stabilisation, attitude against bitumen (NB = not compatible with bitumen, BV = compatible with bitumen), total width ... mm, thickness of expansion part ... mm, Leschuplast GLT type SFA .... / ISA/R ....
|
|
|
|
|
|
General details:
Angle-, T - piece and crossing - connections always have to be factory - made intersection pieces.
Butt joints made on building site have to be welded homogeneous, waterproof according to manufacturers instructions and have to be included into the unit price; Fastening materials wont charged separately. Close adjoining of formwork and possible difficulties from interference by formwork and reinforcement are satisfied with the unit price.
Waterstops will be calculated depending on their biggest length (bevel cuts, miters), intersection pieces will be quantified overall.
|
|
|
|