Combination construction joint waterstop (KAB) the simple, easy and safe sealing of construction joints
Functional principle The KAB profile is a waterstop with an integrated hydropholic gasket profile used for the sealing of construction joints in concrete structures. The KAB consists of a high-grade semi-hard PVC-P material and a round swelling rubber profile (gasket) with a capacity for high volume expansion. The sealing capabilities of the KAB waterstop have been successfully tested and proven in practical use by employing concrete-encased test modules. Even under high water pressure both sealing elements - ribbed sealing and swelling profile - have proven to function in an impressing way without failure. The combination construction joint waterstops are used successfully for years in clarification plants, swimming pools, water supply tanks, basement garages and in domestic buildings
Test certificates supporting these experiments are available on request.
The combination construction joint waterstop is distinguished by cost effectiveness, easy installation and reliability.
- Without floor setting edge or adaptation in the reinforcement of floor sections
- Easy, quick and reliable laying
- high inherent stability
- coils of 25 m length which means less jointing
- small bend radius (edges can be bent)
- low weight (one 25 m coil is about approx. 25 kg)
- no risk of injuries by sharp edges
|
|
- Reliable sealing results are provided by
- ribbed part of profile (labyrinth sealing system)
- round swelling rubber profile (swelling pressure when expose to water)
Application instructions (floor / wall) The swelling rubber part of profile prevents the water from intruding into the bottom area, the ribbed part of profile prevents the water from intruding into the wall area. Installation of the KAB can be carried out at two different points of time:
- before the concrete pour
- during or just after the concrete pour
- When installing before the concrete pour of the bottom, the KAB has to be installed directly on the bottom reinforcement by using steel bars at a distance of 0,5 m.
- When installing during or just after the concrete pour of the bottom, the KAB with the attached steel bars will only have to be pushed into the fresh concrete. After this the concrete has to be compressed.
- The marking strip of 2,5 cm width is located at a height of 2,5 cm up to 5,0 cm and serves as an installation control. The max. linking depth of the profile bottom with the swelling rubber is 5,0 cm.
- Joints can be connected and installed in different ways:
- With terminal strips, which were especially developed for combination construction joint waterstops. Basic principle are 3 swelling rubber profiles with a capacity for high volume expansion and terminal strips of 2 mm thickness, which will be connected with the punched waterstop by butterfly nuts. For punching the waterstop, the terminal strip will be used as a template (5 mm drill bit). The swelling rubber profiles will be delivered prepunched and should be sticked together as pictured leftside. The butterfly nuts should be fixed hand - screwed. Connections with the terminal strips are also possible with internal and external expansion joint waterstops.
- Butt joint weldings with an axe shaped welding tool (the round swelling rubber profile can be taken out of the notch in the welding area temporarily, to remove it after the welding in the cleaned notch).
- Overlapping welding with hot air blower. The overlap should be 5 cm and the riffle must be deleted on the whole width. The contact surfaces are smelting by the hot air concurrently and have to pressed against each other.
- Parallel installation on a distance of approx. 50 cm with a gap of 5 cm (in areas under high water pressure connections with terminal strips or weldings are preferable).
Application instructions (wall/ceiling) The long part of profile has to be pushed into the fresh concrete up to the marking strip, on the top of the wall during the first concrete pour section. After this the concrete has to be compressed. The round swelling rubber profile must be covered as far as the second concrete pour section will take place, to avoid a swelling ahead of time due to rain.
Storage The swelling rubber is activated by water contact. Therefore, it is important to provide storage in a dry place away from moisture.
|
Our waterstops are available in two material qualities "DIN 18541 PVC-P-NBR combined polymerisat" and "Standard Specification PVC-P". Both materials are available in "NB" = not compatible with bitumen and "BV" = compatible with bitumen according to DIN 16937.
|
|
DIN 18541 PVC-P-NBR combined polymerisat (external quality control by MPA NRW)
|
attitude against bitumen: NB = not compatible with bitumen BV = compatible with bitumen
|
|
physical properties (extract)
|
waterstops, waterstops for capping joints and profiles
|
test according to DIN
|
|
Elongation at break at + 23° C
|
350 %
|
53455
|
|
|
Tensile strength
|
10 N/mm²
|
53455
|
|
|
Shore A-hardness
|
70 +- 2
|
53505
|
|
Waterstops and profiles without geometrically accordance to DIN 18541, will be delivered according to DIN 18541 part 2, table 1. Further applications must be specified separately.
|
|
Concerning the actual state of the DIBt (german institute of civil engeneering) in consultation with the authorities of construction inspection of the federal states created building regulations, for protection against pressing and not pressing water also against soil humidity, its only allowed to use waterstops in accordance to:
|
Standard Specification PVC-P (internal quality control, without AbP)
|
attitude against bitumen: NB = not compatible with bitumen BV = compatible with bitumen according to DIN 16937
|
|
physical properties (extract)
|
waterstops, waterstops for capping joints and profiles
|
test according to DIN
|
|
Elongation at break at + 23° C
|
275 %
|
53455
|
|
|
Tensile strength
|
7,5 N/mm²
|
53455
|
|
|
Shore A-hardness
|
73 +- 2
|
53505
|
|
Standard intersection pieces leg length 0,50 m (dimension between axes)

Waterstop intersection pieces and systems
On placing an order of standard intersection pieces, quantity, design, type of waterstop and material quality have to be declared.
For making of waterstop systems it s necessary for us to have dimensioned as possible isometric system drawings with designation about type of waterstop and material quality.
Every declared dimension has to be dimension between axes.

|
pos.
|
quantity
|
specification of services
|
unit price
|
all round price
|
|
|
...running meter
|
Leschuplast GLT combination construction joint waterstop with AbP (General Construction Supervision Certificate), for sealing of construction joints without floor setting edge, consisting of semi-hard PVC-P material and integrated round swelling rubber profile, total width ... mm, incl. steel bars for installation (2 pcs. / m), Leschuplast GLT type KAB ... Set
|
|
|
|
|
|
General details:
Angle-, T - piece and crossing - connections always have to be factory - made intersection pieces.
Butt joints made on building site have to be welded homogeneous, waterproof according to manufacturers instructions and have to be included into the unit price; Fastening materials wont charged separately. Close adjoining of formwork and possible difficulties from interference by formwork and reinforcement are satisfied with the unit price.
Waterstops will be calculated depending on their biggest length (bevel cuts, miters), intersection pieces will be quantified overall.
|
|
|
|